Global event correlation allows to reach out over all metrics monitored by Zabbix and create correlations.
It is possible to correlate events created by completely different triggers and apply the same operations to them all. By creating intelligent correlation rules it is actually possible to save yourself from thousands of repetitive notifications and focus on root causes of a problem!
Global event correlation is a powerful mechanism, which allows you to untie yourself from one-trigger based problem and resolution logic. So far, a single problem event was created by one trigger and we were dependent on that same trigger for the problem resolution. We could not resolve a problem created by one trigger with another trigger. But with event correlation based on event tagging, we can.
For example, a log trigger may report application problems, while a polling trigger may report the application to be up and running. Taking advantage of event tags you can tag the log trigger as Status: Down while tag the polling trigger as Status: Up. Then, in a global correlation rule you can relate these triggers and assign an appropriate operation to this correlation such as closing the old events.
In another use, global correlation can identify similar triggers and apply the same operation to them. What if we could get only one problem report per network port problem? No need to report them all. That is also possible with global event correlation.
Global event correlation is configured in correlation rules. A correlation rule defines how the new problem events are paired with existing problem events and what to do in case of a match (close the new event, close matched old events by generating corresponding OK events). If a problem is closed by global correlation, it is reported in the Info column of Monitoring → Problems.
Configuring global correlation rules is available to Super Admin level users only.
Event correlation must be configured very carefully, as it can negatively affect event processing performance or, if misconfigured, close more events than was intended (in the worst case even all problem events could be closed).
To configure global correlation safely, observe the following important tips:
See also: known issues.
To configure event correlation rules globally:
All mandatory input fields are marked with a red asterisk.
Parameter | Description |
---|---|
Name | Unique correlation rule name. |
Type of calculation | The following options of calculating conditions are available: And - all conditions must be met Or - enough if one condition is met And/Or - AND with different condition types and OR with the same condition type Custom expression - a user-defined calculation formula for evaluating action conditions. It must include all conditions (represented as uppercase letters A, B, C, ...) and may include spaces, tabs, brackets ( ), and (case sensitive), or (case sensitive), not (case sensitive). |
Conditions | List of conditions. See below for details on configuring a condition. |
Description | Correlation rule description. |
Enabled | If you mark this checkbox, the correlation rule will be enabled. |
To configure details of a new condition, click on in the Conditions block. A popup window will open where you can edit the condition details.
Parameter | Description |
---|---|
New condition | Select a condition for correlating events. Note that if no old event condition is specified, all old events may be matched and closed. Similarly if no new event condition is specified, all new events may be matched and closed. The following conditions are available: Old event tag - specify the old event tag for matching. New event tag - specify the new event tag for matching. New event host group - specify the new event host group for matching. Event tag pair - specify new event tag and old event tag for matching. In this case there will be a match if the values of the tags in both events match. Tag names need not match. This option is useful for matching runtime values, which may not be known at the time of configuration (see also Example 1). Old event tag value - specify the old event tag name and value for matching, using the following operators: equals - has the old event tag value does not equal - does not have the old event tag value contains - has the string in the old event tag value does not contain - does not have the string in the old event tag value New event tag value - specify the new event tag name and value for matching, using the following operators: equals - has the new event tag value does not equal - does not have the new event tag value contains - has the string in the new event tag value does not contain - does not have the string in the new event tag value |
Parameter | Description |
---|---|
Operations | List of operations, selected from the New operation field. |
New operation | Select operation to perform when event is correlated and click on Add. The following operations are available: Close old events - close old events when a new event happens. Always add a condition based on the old event when using the Close old events operation or all existing problems could be closed. Close new event - close the new event when it happens |
Because misconfiguration is possible, when similar event tags may be created for unrelated problems, please review the cases outlined below!
Stop repetitive problem events from the same network port.
This global correlation rule will correlate problems if Host and Port tag values exist on the trigger and they are the same in the original event and the new one.
This operation will close new problem events on the same network port, keeping only the original problem open.