Source: https://git.zabbix.com/projects/ZBX/repos/zabbix/browse/templates/server/dell/dell_r820_snmp

DELL PowerEdge R820 by SNMP

Overview

This is a template for monitoring DELL PowerEdge R820 servers with iDRAC version 7 and later via Zabbix SNMP agent that works without any external scripts.

Requirements

Zabbix version: 7.2 and higher.

Tested versions

This template has been tested on:

  • DELL PowerEdge R820

Configuration

Zabbix should be configured according to the instructions in the Templates out of the box section.

Setup

Refer to the vendor documentation.

Macros used

Name Description Default
{$SENSOR.TEMP.STATUS.OK}

The OK status of the temperature probe for trigger expression.

3
{$SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"}

The warning status of the temperature probe for trigger expression.

4
{$SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}

The warning status of the temperature probe for trigger expression.

7
{$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"}

The critical status of the temperature probe for trigger expression.

5
{$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"}

The critical status of the temperature probe for trigger expression.

6
{$SENSOR.TEMP.STATUS.CRIT:"criticalLower"}

The critical status of the temperature probe for trigger expression.

8
{$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}

The critical status of the temperature probe for trigger expression.

9
{$HEALTH.STATUS.DISASTER}

The disaster status of the health for trigger expression.

6
{$HEALTH.STATUS.CRIT}

The critical status of the health for trigger expression.

5
{$HEALTH.STATUS.WARN}

The warning status of the health for trigger expression.

4
{$PSU.STATUS.WARN:"nonCritical"}

The warning value of the PSU sensor for trigger expression.

4
{$PSU.STATUS.CRIT:"critical"}

The critical value of the PSU sensor for trigger expression.

5
{$PSU.STATUS.CRIT:"nonRecoverable"}

The critical value of the PSU sensor for trigger expression.

6
{$FAN.STATUS.WARN:"nonCriticalUpper"}

The warning value of the FAN sensor for trigger expression.

4
{$FAN.STATUS.WARN:"nonCriticalLower"}

The warning value of the FAN sensor for trigger expression.

7
{$FAN.STATUS.CRIT:"criticalUpper"}

The critical value of the FAN sensor for trigger expression.

5
{$FAN.STATUS.CRIT:"nonRecoverableUpper"}

The critical value of the FAN sensor for trigger expression.

6
{$FAN.STATUS.CRIT:"criticalLower"}

The critical value of the FAN sensor for trigger expression.

8
{$FAN.STATUS.CRIT:"nonRecoverableLower"}

The critical value of the FAN sensor for trigger expression.

9
{$FAN.STATUS.CRIT:"failed"}

The critical value of the FAN sensor for trigger expression.

10
{$DISK.ARRAY.STATUS.FAIL}

The disaster status of the disk array for trigger expression.

6
{$DISK.ARRAY.STATUS.CRIT}

The critical status of the disk array for trigger expression.

5
{$DISK.ARRAY.STATUS.WARN}

The warning status of the disk array for trigger expression.

4
{$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}

The critical status of the disk array cache battery for trigger expression.

3
{$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}

The warning status of the disk array cache battery for trigger expression.

4
{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK}

The OK status of the disk array cache battery for trigger expression.

2
{$VDISK.STATUS.CRIT:"failed"}

The critical status of the virtual disk for trigger expression.

3
{$VDISK.STATUS.WARN:"degraded"}

The warning status of the virtual disk for trigger expression.

4
{$DISK.STATUS.WARN:"nonCritical"}

The warning status of the disk for trigger expression.

4
{$DISK.STATUS.FAIL:"critical"}

The critical status of the disk for trigger expression.

5
{$DISK.STATUS.FAIL:"nonRecoverable"}

The critical status of the disk for trigger expression.

6
{$DISK.SMART.STATUS.FAIL}

The critical S.M.A.R.T status of the disk for trigger expression.

1
{$SNMP.TIMEOUT}

The time interval for SNMP agent availability trigger expression.

5m

Items

Name Description Type Key and additional info
Overall system health status

MIB: IDRAC-MIB-SMIv2

This attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc.

SNMP agent dell.server.status[globalSystemStatus]

Preprocessing

  • Discard unchanged with heartbeat: 6h

Hardware model name

MIB: IDRAC-MIB-SMIv2

This attribute defines the model name of the system.

SNMP agent dell.server.hw.model[systemModelName]

Preprocessing

  • Discard unchanged with heartbeat: 6h

Hardware serial number

MIB: IDRAC-MIB-SMIv2

This attribute defines the service tag of the system.

SNMP agent dell.server.hw.serialnumber[systemServiceTag]

Preprocessing

  • Discard unchanged with heartbeat: 6h

Operating system

MIB: IDRAC-MIB-SMIv2

This attribute defines the name of the operating system that the host is running.

SNMP agent dell.server.sw.os[systemOSName]

Preprocessing

  • Discard unchanged with heartbeat: 1d

Firmware version

MIB: IDRAC-MIB-SMIv2

This attribute defines the firmware version of a remote access card.

SNMP agent dell.server.hw.firmware[racFirmwareVersion]

Preprocessing

  • Discard unchanged with heartbeat: 1d

Uptime (network)

MIB: SNMPv2-MIB

The time (in hundredths of a second) since the network management portion of the system was last re-initialized.

SNMP agent dell.server.net.uptime[sysUpTime]

Preprocessing

  • Custom multiplier: 0.01

Uptime (hardware)

MIB: HOST-RESOURCES-MIB

The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.

SNMP agent dell.server.hw.uptime[hrSystemUptime]

Preprocessing

  • Check for not supported value: any error

    ⛔️Custom on fail: Set value to: 0

  • Custom multiplier: 0.01

SNMP traps (fallback)

The item is used to collect all SNMP traps unmatched by other snmptrap items

SNMP trap snmptrap.fallback
System location

MIB: SNMPv2-MIB

The physical location of this node (e.g., 'telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.

SNMP agent dell.server.location[sysLocation]

Preprocessing

  • Discard unchanged with heartbeat: 6h

System contact details

MIB: SNMPv2-MIB

The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.

SNMP agent dell.server.contact[sysContact]

Preprocessing

  • Discard unchanged with heartbeat: 1d

System object ID

MIB: SNMPv2-MIB

The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining 'what kind of box' is being managed. For example, if vendor 'Flintstones, Inc.' was assigned the subtree 1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its 'Fred Router'.

SNMP agent dell.server.objectid[sysObjectID]

Preprocessing

  • Discard unchanged with heartbeat: 6h

System name

MIB: SNMPv2-MIB

An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.

SNMP agent dell.server.name[sysName]

Preprocessing

  • Discard unchanged with heartbeat: 6h

System description

MIB: SNMPv2-MIB

A textual description of the entity. This value should

include the full name and version identification of the system's hardware type, software operating-system, and

networking software.

SNMP agent dell.server.descr[sysDescr]

Preprocessing

  • Discard unchanged with heartbeat: 1d

SNMP agent availability Zabbix internal zabbix[host,snmp,available]

Preprocessing

  • Discard unchanged with heartbeat: 6h

Triggers

Name Description Expression Severity Dependencies and additional info
System is in unrecoverable state

Please check the device for faults.

last(/DELL PowerEdge R820 by SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.DISASTER} Disaster
System status is in critical state

Please check the device for errors.

last(/DELL PowerEdge R820 by SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.CRIT} High
System status is in warning state

Please check the device for warnings.

last(/DELL PowerEdge R820 by SNMP/dell.server.status[globalSystemStatus])={$HEALTH.STATUS.WARN} Warning Depends on:
  • System status is in critical state
Device has been replaced

Device serial number has changed. Acknowledge to close the problem manually.

last(/DELL PowerEdge R820 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0 Info Manual close: Yes
Operating system description has changed

Operating system description has changed. Possibly, the system has been updated or replaced. Acknowledge to close the problem manually.

last(/DELL PowerEdge R820 by SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.sw.os[systemOSName]))>0 Info Manual close: Yes
Firmware has changed

Firmware version has changed. Acknowledge to close the problem manually.

last(/DELL PowerEdge R820 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0 Info Manual close: Yes
Host has been restarted

Uptime is less than 10 minutes.

(last(/DELL PowerEdge R820 by SNMP/dell.server.hw.uptime[hrSystemUptime])>0 and last(/DELL PowerEdge R820 by SNMP/dell.server.hw.uptime[hrSystemUptime])<10m) or (last(/DELL PowerEdge R820 by SNMP/dell.server.hw.uptime[hrSystemUptime])=0 and last(/DELL PowerEdge R820 by SNMP/dell.server.net.uptime[sysUpTime])<10m) Warning Manual close: Yes
System name has changed

The name of the system has changed. Acknowledge to close the problem manually.

last(/DELL PowerEdge R820 by SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.name[sysName]))>0 Info Manual close: Yes
No SNMP data collection

SNMP is not available for polling. Please check device connectivity and SNMP settings.

max(/DELL PowerEdge R820 by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 Warning

LLD rule Temperature discovery

Name Description Type Key and additional info
Temperature discovery

Scanning table of Temperature Probe Table IDRAC-MIB-SMIv2::temperatureProbeTable

SNMP agent temp.discovery

Preprocessing

  • Discard unchanged with heartbeat: 6h

Item prototypes for Temperature discovery

Name Description Type Key and additional info
{#SENSOR_LOCALE} Value

MIB: IDRAC-MIB-SMIv2

This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, the value returned for this attribute is the temperature that the probe is reading in Centigrade. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, a value is not returned for this attribute.

SNMP agent dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]

Preprocessing

  • Custom multiplier: 0.1

  • Discard unchanged with heartbeat: 6h

{#SENSOR_LOCALE} Status

MIB: IDRAC-MIB-SMIv2

This attribute defines the probe status of the temperature probe.

Possible values:

other(1), -- probe status is not one of the following:

unknown(2), -- probe status is unknown (not known or monitored)

ok(3), -- probe is reporting a value within the thresholds

nonCriticalUpper(4), -- probe has crossed the upper noncritical threshold

criticalUpper(5), -- probe has crossed the upper critical threshold

nonRecoverableUpper(6), -- probe has crossed the upper non-recoverable threshold

nonCriticalLower(7), -- probe has crossed the lower noncritical threshold

criticalLower(8), -- probe has crossed the lower critical threshold

nonRecoverableLower(9), -- probe has crossed the lower non-recoverable threshold

failed(10) -- probe is not functional

SNMP agent dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 6h

Trigger prototypes for Temperature discovery

Name Description Expression Severity Dependencies and additional info
Probe {#SENSOR_LOCALE} is in critical status

Please check the device for faults.

last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"} Average
Probe {#SENSOR_LOCALE} is in warning status

Please check the device for faults.

last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"} Warning Depends on:
  • Probe {#SENSOR_LOCALE} is in critical status
Probe {#SENSOR_LOCALE} is not in optimal status

Please check the device for faults.

last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$SENSOR.TEMP.STATUS.OK} Info Manual close: Yes
Depends on:
  • Probe {#SENSOR_LOCALE} is in critical status
  • Probe {#SENSOR_LOCALE} is in warning status

LLD rule PSU discovery

Name Description Type Key and additional info
PSU discovery

IDRAC-MIB-SMIv2::powerSupplyTable

SNMP agent psu.discovery

Preprocessing

  • Discard unchanged with heartbeat: 6h

Item prototypes for PSU discovery

Name Description Type Key and additional info
{#PSU_DESCR}

MIB: IDRAC-MIB-SMIv2

0600.0012.0001.0005 This attribute defines the status of the power supply.

SNMP agent dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 6h

Trigger prototypes for PSU discovery

Name Description Expression Severity Dependencies and additional info
Power supply {#PSU_DESCR} is in critical state

Please check the power supply unit for errors.

last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"nonRecoverable"} Average
Power supply {#PSU_DESCR} is in warning state

Please check the power supply unit for errors.

last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$PSU.STATUS.WARN:"nonCritical"} Warning Depends on:
  • Power supply {#PSU_DESCR} is in critical state

LLD rule FAN discovery

Name Description Type Key and additional info
FAN discovery

IDRAC-MIB-SMIv2::coolingDeviceTable

SNMP agent fan.discovery

Preprocessing

  • Discard unchanged with heartbeat: 6h

Item prototypes for FAN discovery

Name Description Type Key and additional info
{#FAN_DESCR} Status

MIB: IDRAC-MIB-SMIv2

This attribute defines the probe status of the cooling device.

SNMP agent dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 6h

{#FAN_DESCR} Speed

MIB: IDRAC-MIB-SMIv2

This attribute defines the reading for a cooling device

of subtype other than coolingDeviceSubTypeIsDiscrete. When the value

for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the

value returned for this attribute is the speed in RPM or the OFF/ON value

of the cooling device. When the value for coolingDeviceSubType is

coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute.

SNMP agent dell.server.sensor.fan.speed[coolingDeviceReading.{#SNMPINDEX}]

Trigger prototypes for FAN discovery

Name Description Expression Severity Dependencies and additional info
{#FAN_DESCR} is in critical state

Please check the fan unit.

last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"failed"} Average
{#FAN_DESCR} is in warning state

Please check the fan unit.

last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}])={$FAN.STATUS.WARN:"nonCriticalLower"} Warning Depends on:
  • {#FAN_DESCR} is in critical state

LLD rule Array controller discovery

Name Description Type Key and additional info
Array controller discovery

Scanning table of Array controllers: IDRAC-MIB-SMIv2::controllerTable

SNMP agent array.discovery

Preprocessing

  • Discard unchanged with heartbeat: 6h

Item prototypes for Array controller discovery

Name Description Type Key and additional info
{#CNTLR_NAME} Status

MIB: IDRAC-MIB-SMIv2

The status of the controller itself without the propagation of any contained component status.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

SNMP agent dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 6h

{#CNTLR_NAME} Model

MIB: IDRAC-MIB-SMIv2

The controller's name as represented in Storage Management.

SNMP agent dell.server.hw.diskarray.model[controllerName.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 6h

Trigger prototypes for Array controller discovery

Name Description Expression Severity Dependencies and additional info
{#CNTLR_NAME} is in unrecoverable state

Please check the device for faults.

last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.FAIL} Disaster
{#CNTLR_NAME} is in critical state

Please check the device for faults.

last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT} High Depends on:
  • {#CNTLR_NAME} is in unrecoverable state
{#CNTLR_NAME} is in warning state

Please check the device for faults.

last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN} Average Depends on:
  • {#CNTLR_NAME} is in critical state
  • {#CNTLR_NAME} is in unrecoverable state

LLD rule Array controller cache discovery

Name Description Type Key and additional info
Array controller cache discovery

Scanning table of Array controllers: IDRAC-MIB-SMIv2::batteryTable

SNMP agent array.cache.discovery

Preprocessing

  • Discard unchanged with heartbeat: 6h

Item prototypes for Array controller cache discovery

Name Description Type Key and additional info
{#BATTERY_NAME} Status

MIB: IDRAC-MIB-SMIv2

Current state of battery.

Possible values:

1: The current state could not be determined.

2: The battery is operating normally.

3: The battery has failed and needs to be replaced.

4: The battery temperature is high or charge level is depleting.

5: The battery is missing or not detected.

6: The battery is undergoing the re-charge phase.

7: The battery voltage or charge level is below the threshold.

SNMP agent dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 6h

Trigger prototypes for Array controller cache discovery

Name Description Expression Severity Dependencies and additional info
{#BATTERY_NAME} is in critical state

Please check the device for faults.

last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT} Average
{#BATTERY_NAME} is in warning state

Please check the device for faults.

last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN} Warning Depends on:
  • {#BATTERY_NAME} is in critical state
{#BATTERY_NAME} is not in optimal state

Please check the device for faults.

last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK} Warning Depends on:
  • {#BATTERY_NAME} is in critical state
  • {#BATTERY_NAME} is in warning state

LLD rule Physical disk discovery

Name Description Type Key and additional info
Physical disk discovery

Scanning table of physical drive entries IDRAC-MIB-SMIv2::physicalDiskTable.

SNMP agent physicaldisk.discovery

Preprocessing

  • Discard unchanged with heartbeat: 6h

Item prototypes for Physical disk discovery

Name Description Type Key and additional info
{#DISK_NAME} Status

MIB: IDRAC-MIB-SMIv2

The status of the physical disk itself without the propagation of any contained component status.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

SNMP agent dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 6h

{#DISK_NAME} S.M.A.R.T. Status

MIB: IDRAC-MIB-SMIv2

Indicates whether the physical disk has received a predictive failure alert.

SNMP agent dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 6h

{#DISK_NAME} Serial number

MIB: IDRAC-MIB-SMIv2

The physical disk's unique identification number from the manufacturer.

SNMP agent dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 6h

{#DISK_NAME} Model name

MIB: IDRAC-MIB-SMIv2

The model number of the physical disk.

SNMP agent dell.server.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 6h

{#DISK_NAME} Media type

MIB: IDRAC-MIB-SMIv2

The media type of the physical disk. Possible Values:

1: The media type could not be determined.

2: Hard Disk Drive (HDD).

3: Solid State Drive (SSD).

SNMP agent dell.server.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 6h

{#DISK_NAME} Size

MIB: IDRAC-MIB-SMIv2

The size of the physical disk in megabytes.

SNMP agent dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]

Preprocessing

  • Custom multiplier: 1048576

  • Discard unchanged with heartbeat: 6h

Trigger prototypes for Physical disk discovery

Name Description Expression Severity Dependencies and additional info
{#DISK_NAME} failed

Please check physical disk for warnings or errors.

last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"nonRecoverable"} High
{#DISK_NAME} is in warning state

Please check physical disk for warnings or errors.

last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DISK.STATUS.WARN:"nonCritical"} Warning Depends on:
  • {#DISK_NAME} failed
{#DISK_NAME} S.M.A.R.T. failed

Disk probably requires replacement.

last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"} High Depends on:
  • {#DISK_NAME} failed
{#DISK_NAME} has been replaced

{#DISK_NAME} serial number has changed. Acknowledge to close the problem manually.

last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0 Info Manual close: Yes

LLD rule Virtual disk discovery

Name Description Type Key and additional info
Virtual disk discovery

IDRAC-MIB-SMIv2::virtualDiskTable

SNMP agent virtualdisk.discovery

Preprocessing

  • Discard unchanged with heartbeat: 6h

Item prototypes for Virtual disk discovery

Name Description Type Key and additional info
{#DISK_NAME} Status

MIB: IDRAC-MIB-SMIv2

The current state of this virtual disk (which includes any member physical disks.)

Possible states:

1: The current state could not be determined.

2: The virtual disk is operating normally or optimally.

3: The virtual disk has encountered a failure. Data on the disk is lost or is about to be lost.

4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks.

The data on the virtual disk might no longer be fault tolerant.

SNMP agent dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 6h

{#DISK_NAME} Layout type

MIB: IDRAC-MIB-SMIv2

The virtual disk's RAID type.

Possible values:

1: Not one of the following

2: RAID-0

3: RAID-1

4: RAID-5

5: RAID-6

6: RAID-10

7: RAID-50

8: RAID-60

9: Concatenated RAID 1

10: Concatenated RAID 5

SNMP agent dell.server.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 6h

{#DISK_NAME} Size

MIB: IDRAC-MIB-SMIv2

The size of the virtual disk in megabytes.

SNMP agent dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]

Preprocessing

  • Custom multiplier: 1048576

  • Discard unchanged with heartbeat: 6h

{#DISK_NAME} Current state

MIB: IDRAC-MIB-SMIv2

The state of the virtual disk when there are progressive operations ongoing.

Possible values:

1: There is no active operation running.

2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration.

3: A Consistency Check (CC) is being performed on the virtual disk.

4: The virtual disk is being initialized.

5: BackGround Initialization (BGI) is being performed on the virtual disk.

SNMP agent dell.server.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}]
{#DISK_NAME} Read policy

MIB: IDRAC-MIB-SMIv2

The read policy used by the controller for read operations on this virtual disk.

Possible values:

1: No Read Ahead.

2: Read Ahead.

3: Adaptive Read Ahead.

SNMP agent dell.server.hw.virtualdisk.readpolicy[virtualDiskReadPolicy.{#SNMPINDEX}]
{#DISK_NAME} Write policy

MIB: IDRAC-MIB-SMIv2

The write policy used by the controller for write operations on this virtual disk.

Possible values:

1: Write Through.

2: Write Back.

3: Force Write Back.

SNMP agent dell.server.hw.virtualdisk.writepolicy[virtualDiskWritePolicy.{#SNMPINDEX}]

Trigger prototypes for Virtual disk discovery

Name Description Expression Severity Dependencies and additional info
{#DISK_NAME} failed

Please check the virtual disk for warnings or errors.

last(/DELL PowerEdge R820 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.CRIT:"failed"} High
{#DISK_NAME} is in warning state

Please check the virtual disk for warnings or errors.

last(/DELL PowerEdge R820 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$VDISK.STATUS.WARN:"degraded"} Average Depends on:
  • {#DISK_NAME} failed

Feedback

Please report any issues with the template at https://support.zabbix.com

You can also provide feedback, discuss the template, or ask for help at ZABBIX forums

Articles and documentation

+ Propose new article

Didn't find integration you need?